Fault
|
Description
|
|
|---|---|---|
|
Water tap icon crossed
|
Low water level
|
|
|
Bell icon & Heat
|
Over temp (Above 45 degrees Celsius)
|
|
|
Bell icon & ICE
|
Freeze conditions (Below 5 degrees Celsius)
|
|
|
ICE
|
Winter Mode
|
|
|
Bell icon & LDF
|
Load failure
|
|
|
Bell icon & Leak
|
Faulty wiring
|
|
|
CLDF
|
Low Flow
|
|
|
FHL
|
Temp difference between sensors is over 5 degrees (Low Flow)
|
|
|
LDF
|
Loose connection on water sensor, Low flow, Low water level
|
|
|
RPH
|
Reminder, time to check pH level
|
|
|
RSA
|
Reminder, time to check sanitize the spa
|
|
|
RCL
|
Reminder, time to clean the filters
|
|
|
RT9
|
Reminder, Time to test the RCD
|
|
|
RDR
|
Reminder, Time to drain and refill
|
|
|
RCO
|
Reminder, Time to clean spa cover
|
|
|
RTR
|
Reminder, time to treat and clean cabinet
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
OH
|
Over temp (above 47 degrees Celsius)
|
|
|
FR
|
Freeze conditions (Below 4 degrees Celsius)
|
|
|
FL
|
Pressure switch failure
|
|
|
E0
|
Shorted Temperature Sensor
|
|
|
E1
|
Open Temperature Sensor
|
|
|
E2
|
Shorted hi-limit sensor
|
|
|
E3
|
Open hi-limit sensor
|
|
|
E4
|
Shorted flow switch
|
|
|
E7
|
Improper electrical connection
|
|
|
FC
|
Filter cycle in operation
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
'Temp' Flashing
|
Pressure switch or temp sensor failed
|
|
|
- - - - Flashing
|
Hi limit tripped
|
|
|
_._._._
|
Open pressure switch
|
|
|
- - - -
|
Closed pressure switch
|
|
|
- - - -
|
Tripped Hi-Limit
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
E0
|
CPU is fully loaded or loose cables
|
|
|
E1
|
Temperature sensor or the heater is faulty
|
|
|
E2
|
Heat pump temp sensor fault
|
|
|
E3
|
Environmental temp sensor fault
|
|
|
E4
|
Insufficient water level
|
|
|
E5
|
Unmatched power input or voltage fluctuations
|
|
|
E6
|
Water pressure sensor fault - FLO error
|
|
|
C
|
Cold / Freeze - (Water temp below 7 degrees Celsius)
|
|
|
H
|
Overheat (Water temp above 43 degrees Celsius)
|
|
|
HH
|
Overheat (Water temp over 45-47 degrees Celsius)
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
'Ready' Icon Flashing
|
Open or closed control senso
|
|
|
- - - -
|
Fault with the Hi-limit
|
|
|
=:=:=:=
|
Open pressure switch
|
|
|
= = = =
|
Closed Pressure Switch
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
'Ready & Power' Icon Flashing
|
Open pressure switch
|
|
|
'Power' blue light flahing
|
Fault with the Hi-limit
|
|
|
'Ready' Green light flahing
|
Fault with the temp sensir
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
FLO
|
Open flow/pressure switch
|
|
|
FLC
|
Closed flow/pressure switch
|
|
|
HL, PrH
|
Failure of Hi-Limit (OH sensor)
|
|
|
Prr
|
Failure of temp sensor
|
|
|
FrEE
|
Possible freeze conditions
|
|
|
Loc
|
Locked Touchpad
|
|
|
CL
|
Current time of day
|
|
|
Econ
|
Economy mode is on
|
|
|
ECdu
|
Economy cycle duration
|
|
|
Flon
|
Filter Cycle on
|
|
|
Fldu
|
Filter cycle duration
|
|
|
. . . (3 flashing dots)
|
Same as FLO or FLC
|
|
|
. . . (With red LED on PCB)
|
Faulty Hi-Limit
|
|
|
0.0, 32F
|
Failure with temp sensor
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
OH
|
Over temperature
|
|
|
COOL
|
Water temp is low (11 degrees lower then set point)
|
|
|
FLO
|
Open Flow/Pressure switch
|
|
|
FLO 2
|
Shorted Flow/Pressure switch
|
|
|
Hold
|
Touchpad buttons pressed to frequently
|
|
|
HOT
|
PCB temperature to high
|
|
|
ICE
|
Freeze protection
|
|
|
ICE 2
|
Freeze protection
|
|
|
PnL
|
Touchpad to PCB communication error
|
|
|
- - - -
|
`Watchdog’ major fault (Spa de-activated)
|
|
|
Sn1
|
Failure of Hi-Limit sensor
|
|
|
Sn3
|
Failure with Temp sensor
|
|
|
PluG
|
Test sensor left plugged in after service
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
OH
|
Over temperature
|
|
|
COOL
|
Water temp is low (11 degrees lower then set point)
|
|
|
FLO
|
Open Flow/Pressure switch
|
|
|
FLO 2
|
Shorted Flow/Pressure switch
|
|
|
Hold
|
Touchpad buttons pressed to frequently
|
|
|
HOT
|
PCB temperature to high
|
|
|
ICE
|
Freeze protection
|
|
|
ICE 2
|
Freeze protection
|
|
|
PnL
|
Touchpad to PCB communication error
|
|
|
- - - -
|
`Watchdog’ major fault (Spa de-activated)
|
|
|
Sn1
|
Failure of Hi-Limit sensor
|
|
|
Sn3
|
Failure with Temp sensor
|
|
|
PluG
|
Test sensor left plugged in after service
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
GCF
|
Not earthed correctly
|
|
|
-.-.-. (red heater light)
|
Over temperature condition
|
|
|
-.-.-. (Green heater light)
|
Water temp is below 4 degrees Celsius
|
|
|
All lights flashing
|
There is a problem with the pump
|
|
|
E01
|
System Error
|
|
|
E02
|
No water flow
|
|
|
E03
|
Water temperature is below 4 degrees Celsius
|
|
|
E04
|
Water temp is to high
|
|
|
E05
|
Pump fault
|
|
|
End
|
System stopped after 72hrs of running, Hold unlock for 3 sec
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
-40
|
Open circuit temp sensor
|
|
|
122
|
Short circuit temp sensor
|
|
|
HI
|
Fault with the Hi-Limit (above 117F/44C)
|
|
|
HI/temp display-alternating
|
Over temp (above 122F/44C)
|
|
|
J11
|
J11 Temp sensor faulty or not plugged in
|
|
|
J12
|
J12 Temp sensor faulty or not plugged in
|
|
|
PSC
|
Closed Pressure switch
|
|
|
PSO
|
Open Pressure switch
|
|
|
Flashing heat light
|
Hi-Limit fault (resent with light or pump key)
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
PL
|
Locked panel (T-Pad)
|
|
|
Cool
|
Anti-freezing mode (Power off)
|
|
|
Freezing
|
Anti-freezing mode (Power on)
|
|
|
ERR
|
Temperature sensor failed
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
HEF
|
Heater is failing to work
|
|
|
FEF
|
Filter is failing to work
|
|
|
BBF
|
Bubbles are failing to work
|
|
|
SPL
|
Freeze condition (Temp below 0 degrees Celsius)
|
|
|
SPH
|
High temperature detected
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
4352, 4353, 4395 Models
|
||
|
LED 1 flash every secong
|
Pressure switch open (Low Flow)
|
|
|
LED 3 flashes every second
|
PCB or temp sensor fault
|
|
|
Director & Turbo Series
|
||
|
LED slow green (2-3 sec interval)
|
Prime fail (Pressure switch open)
|
|
|
LED fast green (1 sec interval)
|
Open pressure switch beyond initial start
|
|
|
LED slow red
|
Failure with temp sensor
|
|
|
LED fast red
|
Hi-limit over temp cut out
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
HEAT
|
Hi-Limit (Water temp over 45 degrees Celsius)
|
|
|
ICE
|
Water temp is below 5 degrees Celsius
|
|
|
CLDF
|
Flow issue, May be a problem with circ pump
|
|
|
E1,FF
|
Failure with the temp sensor
|
|
|
Water pump or tap icon flashing
|
Low water level
|
|
|
Thermometer icon flashing
|
Low flow
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
SN1
|
Failure with the Hi-limit sensor
|
|
|
SN2
|
Failure with the temp sensor
|
|
|
FL1
|
Open Flow/Pressure switch
|
|
|
FL2
|
Closed Flow/Pressure switch
|
|
|
COL
|
Water temp low (11 degrees below set point)
|
|
|
ICE
|
Over temperature (Above 43 degrees Celsius)
|
|
|
OH
|
Over temperature (Above 43 degrees Celsius)
|
|
|
- - -
|
'Watchdog' major fault (Above 48 degrees Celsius)
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
E1
|
Faulty temperature sensor 1
|
|
|
E2
|
Faulty temp sensor 2
|
|
|
E3
|
Heat pump temp sensor fault
|
|
|
E4
|
Low Water level
|
|
|
E5
|
Incorrect input voltage (Too high or Low)
|
|
|
E6
|
Faulty Flow Switch
|
|
|
E8
|
Heat pump compressor pressure fault
|
|
|
C
|
Water temp is below 7 degrees Celsius
|
|
|
H
|
Water temp is above 43 degrees Celsius
|
|
|
HH
|
Spa has over heated (Above 47 degrees Celsius)
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
EN1 / OH
|
Sensor 1 Failed
|
|
|
EN2
|
Sensor 2 Failed
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
ILOC
|
Interlock
|
|
|
FLO
|
Flashing - (Flow switch open) Closed - (Flow switch closed)
|
|
|
FLO2
|
Flow switch closed circuit
|
|
|
Hold
|
Touchpad buttons pressed to frequently
|
|
|
HOT
|
PCB Temp to high
|
|
|
ICE
|
Freeze conditions detected
|
|
|
PnL
|
Panel-PCB communication error
|
|
|
Sn1
|
Hi-Limit Sensor failed
|
|
|
Sn2
|
Short in in-pool temp sensor
|
|
|
Sn3
|
Temp sensor failed
|
|
|
COOL
|
Water temp 11 degrees below set point
|
|
|
PluG
|
Test sensor plug left plugged in after service
|
|
|
- - - -
|
'Watchdog' Major fail (Spa Deactivated)
|
|
|
LOC
|
Touchpad Locked
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
Portapac
|
||
|
00
|
Temp Sensor Fault
|
|
|
'Heat' indicator flashing
|
Over temp (Sensor Fault)
|
|
|
'Power' indicator flashing
|
Over temp resettable device tripped out (45 degrees)
|
|
|
SP1 or SP2
|
Blower speed adjustment (do not alter - Press 'demand')
|
|
|
Digi-Heat
|
||
|
nFL
|
No Flow detected, Pressure switch open
|
|
|
o/t
|
Over temperature (Tripped at 45 degrees Celsius)
|
|
|
00
|
Temperature sensor fault
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
HLEr
|
Hi-limit sensor failure
|
|
|
SEop
|
Temperature sensor open circuit
|
|
|
SESH
|
Temperature sensor short circuit
|
|
|
CoLd
|
Temperature approaching zero degrees Celsius
|
|
|
OH
|
Over heat condition
|
|
|
PSoC
|
Pressure switch open circuit with circ pump
|
|
|
PSoL
|
Pressure switch open with low speed pump
|
|
|
PSoH
|
Pressure switch open with high speed
|
|
|
FPx (1-4)
|
Filtration period
|
|
|
FPxD (1-4)
|
Filtration duration
|
|
|
PUF
|
Post use filtration
|
|
|
SIL
|
Silence period start time
|
|
|
SILd
|
Silence timer duration
|
|
|
ToE
|
Time out error (System shutdown)
|
|
|
UTO
|
User time out
|
|
|
CALB
|
Temperature calibration
|
|
|
CHCL
|
Air blower channel clear
|
|
|
CLDN
|
Cool down cycle
|
|
|
ECL
|
Energy saving cycle
|
|
|
MENU
|
Menu Access
|
|
|
CANC
|
Cancel/discard Changes
|
|
|
SEND
|
Save Changes
|
|
Spa-Craft Is a proudly Australian owned and run company supplying pool and spa equipment to trade customers across Australia and New Zealand.
Sydney Office – 20 Curtis Rd Mulgrave, NSW 2756
Melbourne Office – 13 Lieber Grv Carrum Downs , VIC 3201
Perth Office – 2/30 Discovery Dr Bibra Lake, WA 6163
Email – info@spa-craft.com.au
Phone – 1300 498 819
Great savings on selected products, check-in often for updated lists.
Once submitted, your pool/spa details will be entered into our sizing calculator along with your local weather details provided by the “Bureau of Meteorology”. A personalise evaluation will be emailed to you within 1-2 business days by a Sensaheat product specialist.