Balboa Water Group’s core is a fundamental commitment to the leisure water industry to provide a simple, comprehensive, single-source solution to our product range that includes the highest quality products in electronic control systems, jets, pumps, and white goods and accessories. Our dedication to excellence and quality for more than three decades has earned us the position as the premier, single-source provider of innovative designs state-of-the-art manufacturing, with an unsurpassed reputation for reliability worldwide.
Spa-Craft is proudly the exclusive distributor of Balboa products across Australia & New Zealand.
|
Fault
|
Description
|
|
|---|---|---|
|
PD
|
Power down, on battery back up
|
|
|
OH
|
Overheat
|
|
|
Flo / Fl
|
Flow Problem
|
|
|
Cool
|
Spa is 11 degrees below set temp
|
|
|
ICE / IC
|
Possible freeze condition – Will run all equipment when temperature drops below 6.7 Degrees until the temp goes back over 7.2 Degrees
|
|
|
SN1 / Sn
|
Hi-limit fault
|
|
|
Sn3 / Sn
|
Temp sensor fault
|
|
|
ILOC
|
Interlock fault
|
|
|
Ec / Econ
|
Spa is in economy mode
|
|
|
Std / St
|
Spa is in standard mode
|
|
|
SL / Slp
|
Spa is in sleep mode
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
- - -, - -
|
Temperature not available (economy mode or sleep mode)
|
|
|
- - F, - - C or - -
|
Temperature not available (priming)
|
|
|
CFE, CONFIG
|
Configuration Error (dipswtiches not set-up correctly)
|
|
|
CrC, CHKSUM
|
Failed the program checksum test (Firmware installation)
|
|
|
dr
|
Possible dry heater
|
|
|
drn, DRAINING
|
Pump 1 is on while draining
|
|
|
drY, dy, Heater dry service reqd
|
Verified dry heater
|
|
|
Ecn, Ec
|
Spa is in economy mode
|
|
|
gFI, GFCI
|
Spa could not trip the RCD
|
|
|
HFL, HL HTR Flow low
|
Low Flow (Large difference between sensors)
|
|
|
Hot, Hot-Call SVC
|
Extreme overheat (Pump may be stuck on)
|
|
|
ICE, IC, Freeze COND
|
Potential freeze conditions (Pumps run)
|
|
|
LF, Low Flow
|
Low Flow (Large difference between sensors)
|
|
|
OHH, HH, HTR Temp LMT Service Reqd
|
Heater has overheated
|
|
|
OHS, OH, SPA Temp LMT
|
Spa has overheated
|
|
|
PHH, PH is High lower PH
|
pH Level is high
|
|
|
PHL, PH is low raise PH
|
pH Level is Low
|
|
|
Pr, Priming mode takes 4 Min
|
The spa is operation in priming mode
|
|
|
PSt, Persist fail
|
The Persistent memory cannot be read
|
|
|
Rt9, Test GFCI
|
Reminder time to check the RCD
|
|
|
rCA, Change mineral cartridge
|
Reminder time to change the Nature 2 cartridge
|
|
|
rCH, New filter
|
Reminder time to change the filters
|
|
|
rCL, Clean filter
|
Reminder time to clean the filters
|
|
|
rCO, Clean cover
|
Reminder time to clean the spa Cover
|
|
|
rdr, Drain water
|
Reminder time to drain water
|
|
|
rPH, Check PH
|
Reminder time to check pH levels
|
|
|
rSA, CK Sanitizer
|
Reminder time to check sanitizer levels
|
|
|
rtC, RTC Failure
|
Real time clock cannot be read
|
|
|
rtr, Treat Wood
|
Reminder time to treat wood
|
|
|
SAH, Sanitizer High
|
Sanitizer level is high
|
|
|
SAL, Sanitizer Low
|
Sanitizer level is Low
|
|
|
SbY, Standby Mode
|
Spa is in standby mode
|
|
|
SE, Standard economy
|
Spa is in standard economy mode
|
|
|
SF, Safety Fault
|
There is a suction block (Pipe block)
|
|
|
SLP, SL
|
Spa is in Sleep mode
|
|
|
SnA, SA, Sensor A service Reqd
|
Sensor A is not operating correctly
|
|
|
Snb, Sb, Sensor B service Reqd-
|
Sensor B is not operating correctly
|
|
|
SnS, Sn
|
Sensors are out of balance
|
|
|
Std, St, Standard
|
Spa is in Standard mode
|
|
|
StU, Stuck on-
|
Pump appears to be stuck on
|
|
|
Fault
|
Description
|
|
|---|---|---|
|
1 flash every 3 seconds
|
Hi-limit fault
|
|
|
2 flashes every 3 seconds
|
Pressure switch closed (FLC)
|
|
|
3 flashes every 3 seconds
|
Pressure switch open (FLO)
|
|
|
4 flashes every 3 seconds
|
Temperature sensor fault
|
|
|
Flash (1 sec on, 1 sec off)
|
Hi-Limit (OH)
|
|
|
Flash (Briefly off every sec)
|
Sensor Fault
|
|
|
Flash (Briefly on every sec)
|
Pressure switch fault
|
|
Spa-Craft Is a proudly Australian owned and run company supplying pool and spa equipment to trade customers across Australia and New Zealand.
Sydney Office – 20 Curtis Rd Mulgrave, NSW 2756
Melbourne Office – 13 Lieber Grv Carrum Downs , VIC 3201
Perth Office – 2/30 Discovery Dr Bibra Lake, WA 6163
Email – info@spa-craft.com.au
Phone – 1300 498 819
Great savings on selected products, check-in often for updated lists.
Once submitted, your pool/spa details will be entered into our sizing calculator along with your local weather details provided by the “Bureau of Meteorology”. A personalise evaluation will be emailed to you within 1-2 business days by a Sensaheat product specialist.